- Minimum kontakt ayrışması 3 mm ile direkt açılma mekanizması
- Güvenlik kilidi mekanizması yanlış kullanımları önler
- Kısa montaj derinliği
- Modüler yapı, geçmeli anahtarlarla kolay montaj
Özellikler ve sipariş bilgisi
Ordering information
Switches
|
Rated voltage
|
Pushbutton color
|
Pushbutton size
|
Terminal
|
Contact
|
Order code
|
Standard load
(125 VAC at 5 A,
250 VAC at 3 A,
30 VDC at 3 A)
|
LED
|
24 VDC
|
Red
|
30 dia.
|
Solder terminal
|
SPST-NC
|
A165E-LS-24D-01
|
DPST-NC
|
A165E-LS-24D-02
|
None
|
–
|
SPST-NC
|
A165E-S-01
|
DPST-NC
|
A165E-S-02
|
TPST-NC
|
A165E-S-03U
|
LED
|
24 VDC
|
40 dia.
|
SPST-NC
|
A165E-LM-24D-01
|
DPST-NC
|
A165E-LM-24D-02
|
None
|
–
|
SPST-NC
|
A165E-M-01
|
DPST-NC
|
A165E-M-02
|
TPST-NC
|
A165E-M-03U
|
Note: The above models have a surface indication of “RESET.” Models with “STOP” indication are also available. For further information, contact your Omron representative.
Accessories (order separately)
Item
|
Type
|
Precautions
|
Order code
|
Yellow plate
|
Yellow, 45 dia.
|
Use this as an emergency stop nameplate.
|
A16Z-5070
|
Panel plug
|
Round
|
Used for covering the panel cutouts for future panel expansion.
|
A16ZT-3003
|
Tightening tool
|
–
|
Useful for repetitive mounting. Be careful not to tighten excessively.
|
A16Z-3004
|
Extractor
|
–
|
Convenient for extracting the switch and lamp.
|
A16Z-5080
|
Specifications
Rated voltage
|
Resistive load
|
A165E series
|
A165E_-U series
|
125 VAC
|
5 A
|
1 A
|
250 VAC
|
3 A
|
0.5 A
|
30 VDC
|
3 A
|
1 A
|
Minimum applicable load
|
150 mA at 5 VDC
|
1 mA at 5 VDC
|
Features
|
Characteristics
|
Operating force (OF) max.
|
14.7 N
|
Releasing force (RF) min.
|
0.1 N·m
|
Pretravel (PT)
|
3.5±0.5 mm
(3±0.5 mm In case of A165E_U series)
|
Item
|
Emergency stop switch
|
Allowable operating frequency
|
Mechanical
|
20 operations/minute max.
|
Electrical
|
10 operations/minute max.
|
Insulation resistance
|
100 MΩ min. (at 500 VDC)
|
Dielectric strength
|
1,000 VAC, 50/60 Hz for 1 min between terminals of same polarity
2,000 VAC, 50/60 Hz for 1 min between terminals of different polarity and also between each terminal and ground
1,000 VAC, 50/60 Hz for 1 min between lamp terminals
|
Durability
|
Mechanical
|
100,000 operations min.
|
Electrical
|
100,000 operations min.
|
Ambient temperature
|
Operating: -10 to 55°C (with no icing or condensation)
Storage: -25 to 65°C (with no icing or condensation)
|
Protection against electric shock
|
Class II
|