Acil stop anahtarı

A165E serisi çeşitli kafa yapılarında E-Stop anahtarlarını sunar. Esnek uygulama için, geniş aksesuar yelpazesi mevuttur. Kolay montaj ve bakım için, çeşitli kontakt kombinasyonları mevcuttur.

  • Minimum kontakt ayrışması 3 mm ile direkt açılma mekanizması
  • Güvenlik kilidi mekanizması yanlış kullanımları önler
  • Kısa montaj derinliği
  • Modüler yapı, geçmeli anahtarlarla kolay montaj

Özellikler ve sipariş bilgisi

Ordering information

Switches

Rated voltage

Pushbutton color

Pushbutton size

Terminal

Contact

Order code

Standard load
(125 VAC at 5 A,
250 VAC at 3 A,
30 VDC at 3 A)

LED

24 VDC

Red

30 dia.

Solder terminal

SPST-NC

A165E-LS-24D-01

DPST-NC

A165E-LS-24D-02

None

SPST-NC

A165E-S-01

DPST-NC

A165E-S-02

TPST-NC

A165E-S-03U

LED

24 VDC

40 dia.

SPST-NC

A165E-LM-24D-01

DPST-NC

A165E-LM-24D-02

None

SPST-NC

A165E-M-01

DPST-NC

A165E-M-02

TPST-NC

A165E-M-03U

Note: The above models have a surface indication of “RESET.” Models with “STOP” indication are also available. For further information, contact your Omron representative.

Accessories (order separately)

Item

Type

Precautions

Order code

Yellow plate

Yellow, 45 dia.

Use this as an emergency stop nameplate.

A16Z-5070

Panel plug

Round

Used for covering the panel cutouts for future panel expansion.

A16ZT-3003

Tightening tool

Useful for repetitive mounting. Be careful not to tighten excessively.

A16Z-3004

Extractor

Convenient for extracting the switch and lamp.

A16Z-5080

Specifications

Rated voltage

Resistive load

A165E series

A165E_-U series

125 VAC

5 A

1 A

250 VAC

3 A

0.5 A

30 VDC

3 A

1 A

Minimum applicable load

150 mA at 5 VDC

1 mA at 5 VDC

Features

Characteristics

Operating force (OF) max.

14.7 N

Releasing force (RF) min.

0.1 N·m

Pretravel (PT)

3.5±0.5 mm
(3±0.5 mm In case of A165E_U series)

Item

Emergency stop switch

Allowable operating frequency

Mechanical

20 operations/minute max.

Electrical

10 operations/minute max.

Insulation resistance

100 MΩ min. (at 500 VDC)

Dielectric strength

1,000 VAC, 50/60 Hz for 1 min between terminals of same polarity
2,000 VAC, 50/60 Hz for 1 min between terminals of different polarity and also between each terminal and ground
1,000 VAC, 50/60 Hz for 1 min between lamp terminals

Durability

Mechanical

100,000 operations min.

Electrical

100,000 operations min.

Ambient temperature

Operating: -10 to 55°C (with no icing or condensation)
Storage: -25 to 65°C (with no icing or condensation)

Protection against electric shock

Class II