WL-N

WL-N Serisi Limit Anahtarları Kurulumu Basitleştirir

Modeller stoklamayı kolaylaştırmak için en popüler özelliklere odaklanır.

  • Geliştirilmiş dayanıklılık ve performans
  • Kısaltılmış parça numaraları
  • Kolay kablolama
  • Doğrudan ve ön kablolama
  • Toprak terminal modelleri, EN ve IEC tarafından onaylanmıştır ve CE işareti taşır
  • UL,CSA

 

Özellikler ve Sipariş Bilgisi

Ordering Information

Actuator type

Contact Form and features

Connection method

CE Mark

Order code

Roller lever R38

DPDB

Screw terminal (Pg13,5 conduit with ground terminal)

Yes

WLCA2-2NG-N

Adjustable roller lever: R25 to 89 mm, pretravel 15°±5°

DPDB, Heat-resistant: 5 to 120°C

WLCA12-THG-N

Adjustable roller lever: R25 to 89 mm, pretravel 15°±5°

DPDB, LED

WLCA12-GLD-N

Roller lever R50, pretravel 15°±5°

DPDB

WLCA2-7G-N

Roller lever R63, pre-travel 15°±5°

DPDB

WLCA2-8G-N

Adjustable rod lever: 25 to 140 mm, pretravel 15°±5°

DPDB, Heat-resistant: 5 to 120°C

WLCL-THG-N

Adjustable rod lever: 25 to 140 mm, pretravel 15°±5°

DPDB, LED,

Pre-wired Connector M12 (Smart Click), with ground terminal

WLCL-2NLD-DGJ-N

Roller lever R38, High sensitive pre-travel 10°+2/-1°

DPDB, LED

WLG2-LDFS-DGJS-N

Specifications

Characteristics

Degree of protection

IP67

Durability

Mechanical

15,000,000 operations min.

Electrical

750,000 operations min.

Operating speed

1 mm/s to 1 m/s (in case of WLCA2-N)

Operating frequency

Mechanical

120 operations/minute min.

Electrical

30 operations/minute min.

Rated frequency

50/60 Hz

Insulation resistance

100 MΩ min. (at 500 VDC)

Contact resistance

25 mΩ max. (initial value for the built-in switch when tested alone)

Dielectric strength

Between terminals of the same polarity

1,000 VAC (600 VAC), 50/60 Hz for 1 min

Between currentcarrying metal part and ground

2,200 VAC (1,500 VAC), 50/60 Hz for 1 min

Between each terminal and non-currentcarrying metal part

2,200 VAC (1,500 VAC), 50/60 Hz for 1 min

Vibration resistance

Malfunction

10 to 55 Hz, 1.5-mm double amplitude

Shock resistance

Destruction

1,000 m/s2 max.

Malfunction

300 m/s2

Ambient operating temperature

-10 to 80°C (with no icing)

Ambient operating humidity

35% to 95% RH

Weight

Approx. 255 g (in case of WLCA2-N)

Note: 1. The above figures are initial values.

2. The figures in parentheses for dielectric strength are those for the highsensitivity overtravel models.

Ratings

Item

Rated voltage (V)

Non-inductive load (A)

Inductive load (A)

Resistive load

Lamp load

Inductive load

Motor load

NC

NO

NC

NO

NC

NO

NC

NO

Basic switches

AC

125

10

3

1.5

10

5

2.5

250

10

2

1

10

3

1.5

500

10

1.5

0.8

3

1.5

0.8

DC

8

10

6

3

10

6

14

10

6

3

10

6

30

6

4

3

6

4

125

0.8

0.2

0.2

0.8

0.2

250

0.4

0.1

0.1

0.4

0.1

High-sensitivity switches

AC

125

5

250

5

DC

125

0.4

250

0.2