- Geliştirilmiş dayanıklılık ve performans
- Kısaltılmış parça numaraları
- Kolay kablolama
- Doğrudan ve ön kablolama
- Toprak terminal modelleri, EN ve IEC tarafından onaylanmıştır ve CE işareti taşır
- UL,CSA
Özellikler ve Sipariş Bilgisi
Ordering Information
Actuator type
|
Contact Form and features
|
Connection method
|
CE Mark
|
Order code
|
|
Roller lever R38
|
DPDB
|
Screw terminal (Pg13,5 conduit with ground terminal)
|
Yes
|
WLCA2-2NG-N
|
|
Adjustable roller lever: R25 to 89 mm, pretravel 15°±5°
|
DPDB, Heat-resistant: 5 to 120°C
|
WLCA12-THG-N
|
Adjustable roller lever: R25 to 89 mm, pretravel 15°±5°
|
DPDB, LED
|
WLCA12-GLD-N
|
|
Roller lever R50, pretravel 15°±5°
|
DPDB
|
WLCA2-7G-N
|
Roller lever R63, pre-travel 15°±5°
|
DPDB
|
WLCA2-8G-N
|
|
Adjustable rod lever: 25 to 140 mm, pretravel 15°±5°
|
DPDB, Heat-resistant: 5 to 120°C
|
WLCL-THG-N
|
Adjustable rod lever: 25 to 140 mm, pretravel 15°±5°
|
DPDB, LED,
|
Pre-wired Connector M12 (Smart Click), with ground terminal
|
WLCL-2NLD-DGJ-N
|
|
Roller lever R38, High sensitive pre-travel 10°+2/-1°
|
DPDB, LED
|
WLG2-LDFS-DGJS-N
|
Specifications
Characteristics
Degree of protection
|
IP67
|
Durability
|
Mechanical
|
15,000,000 operations min.
|
Electrical
|
750,000 operations min.
|
Operating speed
|
1 mm/s to 1 m/s (in case of WLCA2-N)
|
Operating frequency
|
Mechanical
|
120 operations/minute min.
|
Electrical
|
30 operations/minute min.
|
Rated frequency
|
50/60 Hz
|
Insulation resistance
|
100 MΩ min. (at 500 VDC)
|
Contact resistance
|
25 mΩ max. (initial value for the built-in switch when tested alone)
|
Dielectric strength
|
Between terminals of the same polarity
|
1,000 VAC (600 VAC), 50/60 Hz for 1 min
|
Between currentcarrying metal part and ground
|
2,200 VAC (1,500 VAC), 50/60 Hz for 1 min
|
Between each terminal and non-currentcarrying metal part
|
2,200 VAC (1,500 VAC), 50/60 Hz for 1 min
|
Vibration resistance
|
Malfunction
|
10 to 55 Hz, 1.5-mm double amplitude
|
Shock resistance
|
Destruction
|
1,000 m/s2 max.
|
Malfunction
|
300 m/s2
|
Ambient operating temperature
|
-10 to 80°C (with no icing)
|
Ambient operating humidity
|
35% to 95% RH
|
Weight
|
Approx. 255 g (in case of WLCA2-N)
|
Note: 1. The above figures are initial values.
2. The figures in parentheses for dielectric strength are those for the highsensitivity overtravel models.
Ratings
Item
|
Rated voltage (V)
|
Non-inductive load (A)
|
Inductive load (A)
|
Resistive load
|
Lamp load
|
Inductive load
|
Motor load
|
NC
|
NO
|
NC
|
NO
|
NC
|
NO
|
NC
|
NO
|
Basic switches
|
AC
|
125
|
10
|
3
|
1.5
|
10
|
5
|
2.5
|
250
|
10
|
2
|
1
|
10
|
3
|
1.5
|
500
|
10
|
1.5
|
0.8
|
3
|
1.5
|
0.8
|
DC
|
8
|
10
|
6
|
3
|
10
|
6
|
14
|
10
|
6
|
3
|
10
|
6
|
30
|
6
|
4
|
3
|
6
|
4
|
125
|
0.8
|
0.2
|
0.2
|
0.8
|
0.2
|
250
|
0.4
|
0.1
|
0.1
|
0.4
|
0.1
|
High-sensitivity switches
|
AC
|
125
|
5
|
–
|
–
|
–
|
250
|
5
|
–
|
–
|
–
|
DC
|
125
|
0.4
|
–
|
–
|
–
|
250
|
0.2
|
–
|
–
|
–
|